- Transfer the selector lever from the situation "R" to situation "1", - pass of each tooth should be defined distinctly to the touch, otherwise, and also in case of failure of the index of position of the lever, make necessary adjustment of a drive.
|
- Return the lever to the situation "R", then release lock-nuts of the coupling coupling.
|
|
- Having delayed the selector lever towards the situation "R" (without button squeezing), rotation of the coupling coupling try to achieve combination it with the cable core.
|
- Release the coupling on one turn and tighten lock-nuts with demanded effort. (4.4 — 5.9 Nanometer).
|
|
- Having transferred the selector lever to situation "1", make sure of smoothness of its moving.
|