Details of fastening of klapanny assembly of management of AT
|
- Remove forward section of system of production of the fulfilled gases.
|
- Remove the case pallet with sealing laying and merge ATF.
|
|
- In case of need remove the sensor of temperature of ATF.
|
|
- Remove the mesh filter.
- Disconnect electroconducting, turn out fixing bolts (try to remember the adjusting provision of bolts) and remove klapanny assembly (see an illustration of the Detail of fastening of klapanny assembly of management of AT).
|
- In case of need make replacement of the failed internal components of klapanny assembly, for extraction of accumulators A, B, C and D use the compressed air.
|
|